Device parameters:

  • Output frequency: 0,01 Hz to 900kHz
  • An electrical signal on electrodes: sine waves - unidirectional
  • Electromagnetic signal: squere wave, unidirectional
  • Coil or mat impedance: 20 - 50om*
  • Output voltage regulated manually from 1,5 to 12V (RMS)
  • Output current from electrodes: from around 500uA 
  • Regulated voltage of the electrodes: 0,5 - 4V 
  • Regulated amplitude of the electrodes signal 1 - 8V
  • Therapy program memory size: 1000 b:
  • Change mat polarity: no 
  • Magnetic induction RMS and during an impulse: adjustable by the choice of coil and mat;
  • Power voltage 12 V;
  • Working time (coli 50 ohms): avg. 3 h;
  • Auto-calibration of the signal voltage output.
  • Control: manual or bioZAP script
  • PC or mobile communication : miniUSB; bluetooth
  • Sockets: miniUSB, coil & power supplier 5pin, hand electrodes
  • Power supplier 14V
  • The function of automatic switching the device off after the end of the therapy
  • LCD screen: 2x16
  • Buzzer - signal communication
  • Numeric keyboard
  • Battery 12V/1,3Ah
  • Battery charging time 1-1.5h
  • Downloading scripts from the portal

Software version:

ver.multizap

The software and hardware version description:

   3 - hardware version – Arduino NANO version
   2018-01-28 - software release date

New version of the software is available for download from the Github website. The update method is described in the fimware upgrade manual.

 

 

 

Magnetic and electro therapy contraindications (safety of use)

Based on the textbook: Fizykoterapia, Wydawnictwo Lekarskie PZWL 2006,  Ph. D Tadeusz Mika & Ph. D Wojciech Kasprzak, ISBN 9788320046632.

  1. Cancer
  2. Pregnancy
  3. Electronic implants. For example, pacemakers, hearing aids and electronically controlled prostheses.
  4. Pulmonary tuberculosis
  5. Bleeding from the gastrointestinal tract
  6. Acute coronary insufficiency
  7. Severe infection of bacterial, viral or fungal origin
  8. Steel implants in animals. Steel implants are not used for people. The pulsating EM field should not be used for postoperative treatment associated with the implantation of steel implants (ferromagnetic materials). The use of magnetotherapy is possible after consultation with a doctor.

In addition, avoid placing the following things less than 1 meter away from the coil or mat:

  1. Electronic devices, including telephones and computers;
  2. Watches, including electronic ones;
  3. Compasses;
  4. Payment cards;
  5. Documents with telemetry data, e.g. passports;
  6. Access cards containing RFID tags, etc;
  7. Devices and objects sensitive to magnetic and electromagnetic fields;
  8. Neodymium magnets;

Please consult your doctor before using this device as a part of your PEMF therapy.

 The freePEMF is not a medical device. Remember that you use the freePEMF device only at your own risk. The author is not responsible for the material and legal consequences of using the freePEMF device on its users, animals, lost revenues and financial losses.

The author designed the device based on his experience as an interesting research project. The freePEMF device has not proper clinical trials on humans or animals, so it is not possible to scientifically confirm its efficiency.

Please note that 15 Hz and 20 Hz frequencies cause anxiety and stress in animals. They should not be used. They are part of the therapy No. 1.

 

 

Keyboard menu

[#] - Turn on - press [#] and hold 3 seconds. [#] is also enter key.

[*] - Escape key or turn-off in main menu.

[A] - Generate frequency 
	1. Set frequency e.g. 10000 = 100.00Hz or use [D] as decimal separator e.g. [1][0][0][D] and press [#]
	2. Set time in seconds and press [#]

[C] - Calibrate and save settings in EEPROM memory
	1. Set vampl - pk-pk apmplitude of sine signal e.g. 400 = 4.00V and press [#] (1.00 - 8.00V)
	2. Set vmin - minimum extremum of sine signal e.g. 100 = 1.00V and press [#] (0.50 - 4.00)
	3. Set calibration frequency or simply press [#]
	
[0] - Start EEPROM therapy script

[1]-[9] Start standard program in flash memory

[B] - TODO: Settings:
	 * auto_turn_off_time - EEPROM
	 * AD985x 0/1 - EEPROM
	 * default_program - EEPROM
	 
[D] - TODO: multiZAP+ function - Select and start express-scan. You need SD card pluged.

 

vampl_vmin

Standard therapy scripts

  1. Chlamydia 36min.  
  2. Candida 21min.  
  3. Mycoplasma 27min.  
  4. Borrelia (1) 30min.   
  5. Borrelia (2) 72min.  
  6. Borrelia (3) 2godz.
  7. Borrelia (4) 72min.  
  8. Earth rythem 8min.
  9. Pinal gland activation 15min.

  1-7. Use electrodes or mat

  4-7. Script therapy set fo borellia.  

  8. Use mat.

  9. Use mat or green coil or orange with signal reductor.

Sources:     

  1-7, 9.: dr. Nenah Silver, Podręcznik Rife'a. Katalog częstotliwości pasożytów – wydawnictwo Enso Publishing 2013, ISBN: 978-83-932269-4-8  

  8.: Bryant Meyers, PEMF The 5th Element of Health –  wydawnictwo Balboa Press 2013, ISBN: 978-1-4525-7923-8

 

bioZAP commands

See: https://github.com/biotronika/multiZAP/wiki

bioZAP language: https://biotronika.pl/en/bioZAP

Therapies: https://biotronika.pl/en/terapie

 

Examples of user scripts

# Pinal gland activation
wait 3000
freq 2000 300
freq 53700 300
freq 66200 300
beep 200
off
@

 

# User script
wait 3000
beep 200
freq 41400 180
freq 46400 180
freq 72750 180
#next command
beep 200
off
@

 

# Test
wait 3000
pbar 100 70

vampl 800
vmin 100

#Label no 1
:1 4

beep 100
freq 1000 5
pin3 ~

jump 1

vmin 400
vampl 100

freq 783 60
beep 100
@